หน้าแรก   EN | TH  
(+66) 095-895-5656 sales_auto@solimacgroup.com
 
ค้นหา
  สินค้า  
 
 
 
  ADLINK Chassis PXIS-2719A
 
  • PXI Hardware Specification Rev. 2.2 compliant
  • Rack-mountable 19-slot PXI chassis with one system slot  and eighteen PXI/CompactPCI peripheral slots
  • Advanced forced-cooling mechanism for efficient and uniform heat dissipation
  • External 10 MHz reference clock input via BNC connector
  • 0°C to 55°C extended operating temperature range
  • Intelligent chassis monitoring/control(Automatic fan speed control,Chassis status monitoring and exporting,Remote chassis power on/off control)
  • 600 W industrial-grade AC power supply
  • Power, temperature and fan monitoring LEDs

 

 

Power Supply   Physical
AC Input
• Input voltage range: 85 to 264 VACfull range
• Input voltage frequency: 47 to 63 Hz
  - Number of slots: 19
(1 system slot + 18 peripheral slots)
- DC Output
• Maximum total usable power is 600 W
  - Dimensions: 444 mm (W) x 178 mm (H) x 455 mm (D)
(17.3" x 6.9" x 17.7")
VDC Maximum Load
Regulation
Maximum Ripple
& Noise
+5 V 45.0 A ±3% 20 mV
+12 V 15.0 A ±3% 50 mV
+3.3 V 42.0 A ±3% 20 mV
-12 V 4.75A ±3% 50 mV
  - Weight: 13.4 kg (29.5 lbs)
Cooling   Operating Environmen
- Fans: 3x 185.9 CFM fans   - Ambient temperature: 0˚C to 55˚C (32˚F to 131˚F
- Per-slot cooling capacity: 25 W
(verified by 55°C chamber test)
  - Relative humidity: 10% to 90%, non-condensing
    Storage Environment
    - Ambient temperature: -20˚C to 70˚C (-4˚F to 158˚F)
    - Relative humidity: 10% to 90%, non-condensing
    Shock and Vibration
    - Functional shock: 30 G, half-sine, 11 ms pulse duration
    - Random vibration:
• Operating: 5 to 500 Hz, 0.31 Grms, 3 axes
• Non-operating: 5 to 500 Hz, 2.46 Grms, 3 axes
    Emissions Compliance
    - EN 61326-1
    - FCC Class A
    CE Compliance
    - Safety: EN 61010-1
    - Immunity: EN 61326-1

 

 
 
Copyright © SOLIMAC AUTOMATION. All Rights Reserved Image Sensing   @SolimacGroup